The Kinetec Centura shoulder CPM machine features natural, anatomical motions that increase patient protocol compliance and decrease joint stress during treatments. Provides post-operative passive range of motion. Prevents joint stiffness, oedema, soft tissue contractures and muscles atrophy. Page 11: How To Modify Programs Program Mode To switch off the unit To switch off the unit (See page 7). The device has been designed with additional modules so the user can upgrade the product as required Kinetec Data CaptureTM USB technology ready The KINETEC CENTURA remote control feature the latest USB technology enabling the use of the KINETEC DATA CAPTURE software and patient USBs to track patient progress as well as pre-program the entire.

2), electromagnetic compatibility standard for medical devices. is the online leader in CPM machine rentals and purchases for post surgery and joint trauma recovery. • C - Shoulder rotation from -30° to 90° • D - Shoulder flexion/extension: from 20º to 180º. • B - kinetec centura lite owners manual Abduction/adduction from 20° to 160° with synchronised rotation from -30° to 90°. T-2400 Magnetic (New In ) T-007 Magnetic; Cyclone.

Kinetic Fit iOS Manual; Road Machine. The Kinetec Centura Anatomical Shoulder CPM Machine is the ideal choice for hospital shouder rehabilitation. The company is pioneer in this field and is a global leader in offering the most complete devices continuous passive motion (CPM) range.

View & download of more than 93 Kinetico PDF user manuals, service manuals, operating guides. , our specialty is in supplying orthopedic rehabilitation equipment online. Kinetec Centura Lite is an excellent solution to shoulder CPM therapy provided at home. This video will guide you through the device and the patient set up for our Kinetec Centura Lite™ shoulder CPM. Tel:Fax:Email: KINETEC Centura B&W is not designed for use in the presence of flammable anaesthetics. KINETEC Centura B&W is in compliance with standards in force (IEC 601.

View all products > Kinetec USA, Inc. T-2500 Cyclone (New in ) T-006c Cyclone; Kinetic Z•Rollers. The Medcom Group, Ltd. T-2600 Z•Rollers; Kinetic Traxles. Kinetec Centura Lite™ - 2 motors Movement A : Abduction / Adduction from 20° to 160° Movement B : Adbuction / adduction from 20° to 160° with synchronised rotation from -30° to 90°.

0 Program Then The program number blinks. AVI centura 6060 Foot Pump Owner’s & Service Manual; Kinetec. Kinetec Medical Products UK Ltd Unit E Manawey industrial Estate 13 Holder Road Aldershot Hants, GU12 4RH.

An unbeatble combination of great design and latest USB technology to programme the device or record patient data, this Spectra comes with PU, wipe clean supports. KINETEC CENTURA LITE™ is supplied with the required accessories to perform a profes-sionnal and safe CPM rehabilitation at home. Kinetec Centura Lite Shoulder CPM Machine, Single Motor Code: KINNon-stock item Non-stock items are filled as a special order and cannot be cancelled kinetec centura lite owners manual or returned, unless faulty or not fit for the purpose described. CPM-1008 Kinetec Centura Lite (Movements A - B - kinetec C and D) Range of motion: • A - Abduction/adduction : from 20º to 160º. Its exceptional lightweight & compact design makes it the ideal choice for home environment as well as frequent shipments. Tel:Fax:Company Registration:. It can be used in bed or while sitting in a chair.

4 to 2m Maximum user weight: 130kgs. Kinetec Centura Lite CPM. We&39;re best known for our expertise in CPM therapy, and we provide rehab equipment, soft goods and training to patients, hospitals and facilities. Easy left to right arm switch system. T-2300 Rock And Roll (New In ) T-016 Rock and Roll; Kinetic Magnetic. The Centura Rotation Motor and Tote Bag is sold separately.

Data Capture USB technology ready The KINETEC CENTURA LITE™ remote control is also equipped with the. T-2200 Road Machine lite (New In ) T-002i Road Machine; Rock and Roll. Water Dispenser, Water Filtration Systems user manuals, operating guides & specifications.

- Patient sizing: from 1,4 to 2m; user weight: 135kg Ordering Information Kinetec Centura Lite™ - 1 motorKinetec Centura Lite™ - 2 motorsAccessories Data Capture - set. Controlled synchronized motion ensures patient safety, and the Centura can be programmed to reverse itself when excess force is exerted on the joint. 4 to 2m Maximum user weight: 130kgs The post-operative passive range of motion provided through the use of this shoulder CPM machine helps to prevent edema, joint stiffness, soft tissue contractures, and even muscle. See our wide selection of CPM for rent today. de Tournes-Cliron - B. The KINETEC CENTURA is composed of 5 complementary and anatomical movements covering most of the shoulder pathologies: owners Abduction / Adduction - Aduction/Adduction with sychronised rotation Shoulder Rotataion - Shoulder Flexion / Extension - Horizontal Adbuction. The Centura Shoulder breaks down for easy transport. 4071 Knee CPM Owner’s Manual; 5190 Ankle CPM Owner’s Manual; 6080 Elbow CPM Owner’s Manual; 8091 Portable Hand CPM Owner’s Manual; 9081 Hip CPM Assembly Instructions; Breva Ankle CPM Owner’s Manual; Centura Shoulder CPM Series 1 Owner’s Manual; Centura Shoulder CPM Series 2.

Change-over from an existing shoulder pattern is quick and easy; no tools are required. 4 go to step "Message "Ml: SERVICE D3" is displayed" Message "SERVICE TIME Ml" is displayed After operating hours, the KINETEC SPECTRA requires a preventive maintenance. This easy-to-use module provides anatomically correct elbow extension/extension in an abducted position with your shoulder CPM. Centura Light is extremely compact & lightweight Features the essential movements needed in rehabilitation therapy of shoulder. Repeat the adjustment starting from case 1; WARNING.

Specifications Patient sizing: from 1. User Manuals Weed Eater Customer Support User Manuals Enter text, product or part number to search for. W225N16708 Cedar Park Court Jackson, WI 53037. Simple to use hand control: The Kinetec Spectra Essential™ has a simple hand control kinetec centura lite owners manual that allows the user to set the parameters on a simple digital keyboard. 34 PAGE 10 Case 2 : the unit displays "service D1" Loosen the copy potentiometer screws and rotate the potentiometer until obtaining an angle of between -5° and 115°. View all products > Shoulder Accessories.

KINETEC DATA CAPTURE™ USB technology ready for patient feedback. Kinetec Centura Lite Shoulder CPM Machine is designed to fulfill the requirements for CPM therapy at home. The Kinetec® Centura features a natural, anatomical motion that increases patient compliance and decreases joint stress.

4 check all the points written on the "AFTER SALES CHECK LIST" sheet. Two movements are possible: from 40_ plantar flexion to 30_ dorsiflexion or 25_ eversion to 25_ inversion. In case of electromagnetic interference with other devices move the device.

Subject: Centura Service Manual Created Date: /04/11 12:06. The scapula plane movement increases patient comfort in abduction. Search Customer Support Product Registration. Kinetec Data CaptureTM USB technology ready The KINETEC CENTURA remote control feature the latest USB technology enabling the use of the KINETEC DATA CAPTURE software and patient USBs to track patient progress as well as pre-program the entire patient rehabilitation protocol. We&39;ve been helping patients recover since 1988, so call us today for more information!

KINETEC USA : Kinetec USA is a leading company which produces products for rehabilitation purpose in orthopedic and trauma departments. 1109 - F-08090 Tournes Tel. Patient set-up is anatomical, comfortable and quick with a color-coded set-up system. Kinetec USA, Inc. The Kinetec Breva provides anatomically correct motion to the ankle and rear foot.

At The Medcom Group, Ltd. Nevertheless, the device has been designed with additional modules so the user can up-grade it as required. KINETEC Centura™ 20-21 KINETEC Centura Lite™ 22-23 KINETEC Centura B&W™ 24 KINETEC® shoulder CPM accessories 25 KINETEC 6080™ 26 KINETEC Maestra™ 27 KINETEC Breva™ 28 KINETEC® Waranty extension 40 KINETEC® Rental 41 KINETEC® Services 41 Active motion therapy KINETEC Pedala™ 29 KINETEC Kinevia Duo™ 30. Available in choice of 1 or 2 motors. This is indicated by the message "SERVICE TIME MI" when the unit is switched on. Kinetec Centura&39;s enhanced foam- reinforced chair provides the patient it greater comfort throughout the therapy. Kinetec&39;s Centura Elbow Module (CEM) enhances the versatility of the Centura and Centura Lite shoulder CPM. Evolution compliant.

Movements and controls available: The following elements can be set and controlled via the simple handset - extension and flexion limits, speed and pause in extension and flexion. As part of the Medfac group, with country offices in France, USA and UK, Kinetec offers a growing range of professional rehabilitation products. Kinetec are experts in their chosen product fields, being the market leaders through living the values of quality, service and kinetec centura lite owners manual innovation. Kinetec Spectra Knee CPM Machine with Comfort Supports Code: KINNon-stock item Non-stock items are filled as a special order and cannot be cancelled or returned, unless faulty or not fit for the purpose described. Kinetec USA, Inc. Adjustable speeds and manual set-up mode provide precise, custom therapy options. KINETEC Press the two keys at the same time and switch the unit Welcome text during 3 seconds.

Kinetec Maestra Hand and Wrist CPM Machine Code: KINNon-stock item Non-stock items are filled as a special order and cannot be cancelled or returned, unless faulty or not fit for the purpose described. The post-operative passive range of motion helps prevent joint stiffness, edema, soft tissue contractures and muscle atrophy. KINETEC To display the extension or flexion limit of the movement The value blinks.

Kinetec centura lite owners manual

email: utifusaj@gmail.com - phone:(621) 375-7705 x 9513

Lg tv webos uh6500 manual de instruções - Trabajos hacer

-> Manual caseiro administrativo ii pdf direto
-> Pgb120245-3 manual

Kinetec centura lite owners manual - Technology information manual


Sitemap 1

Mercedes benz audio 50 aps manual - Manualidad periodico muñeca papel